- Home Page /
- Industrial Supplies /
- Lab & Scientific Products /
- Lab Instruments & Equipment /
- Chromatography /
- LC Columns & Column Supplies /
- MACHEREY-NAGEL 720936.4 Nucleosil 100-5 C18 A...
MACHEREY-NAGEL 720936.4 Nucleosil 100-5 C18 AB HPLC 1 Column, Analytical, 250 mm Length, 4 mm ID, USP L1
XCD 2697
Price Details
Excluding Shipping & Custom charges ( Shipping and custom charges will be calculated on checkout )
*All items will import from US
QTY:
Ubuy works hard to protect your security and privacy. Our advanced payment security system ensures confidentiality by encrypting your information during transmission using AES (Advanced Encryption Standards) and SSL (Secure Socket Layer) protocols. Your payment details are 100% secure as we do not share your payment details with third party sellers.
NUCLEOSIL is one of the first spherical silicas used in HPLC, providing a highly pure and uniform SiO2 structure for precise chromatography.
Fast
Shipping
Free
Return*
Secure Packaging
100% Original Products
PCI DSS Compliance
ISO 27001 Certified
What Stands Out
Product Details
| Item Weight | 0.5 lbs (230 grams) |
Who Should Buy?
-
Analytical Chemists
Ideal for analytical chemists requiring high precision and reliability in HPLC applications for various compounds.
-
Pharmaceutical Research
Suitable for pharmaceutical researchers focusing on drug formulation and analysis, ensuring accurate results in drug monitoring.
-
Environmental Testing
Effective for environmental scientists testing for contaminants, as it provides high-resolution separation for complex samples.
-
Budget-Conscious Users
May not be suitable for users with limited budgets, as high-grade columns can be expensive.
-
Beginners in HPLC
Not ideal for beginners without proper knowledge in HPLC, as it requires some expertise for optimal use.
-
Non-Standard Applications
Users needing columns for niche or non-standard applications may find this product unsuitable for their specific needs.
Product Description
MACHEREY-NAGEL 720936.4 Nucleosil 100-5 C18 AB HPLC 1 Column, Analytical, 250 mm Length, 4 mm ID, USP L1
Customer Questions & Answers
-
Question:
What is the primary use of the MACHEREY-NAGEL 720936.4 Nucleosil 100-5 C18 AB HPLC column?
Answer: The MACHEREY-NAGEL 720936.4 Nucleosil 100-5 C18 AB HPLC column is primarily used for the analytical separation of various compounds in high-performance liquid chromatography (HPLC). Its C18 bonded phase offers excellent selectivity and retention for a wide range of non-polar to moderately polar compounds, making it ideal for applications in pharmaceuticals, environmental testing, and food safety. By choosing this specific C18 column, researchers can achieve enhanced resolution and reproducibility in their analyses. -
Question:
What are the specifications of the MACHEREY-NAGEL 720936.4 Nucleosil 100-5 C18 AB HPLC column?
Answer: The MACHEREY-NAGEL 720936.4 Nucleosil 100-5 C18 AB HPLC column features a length of 250 mm, an inner diameter (ID) of 4 mm, and a USP L1 classification. The 100-5 indicates its particle size of 5 µm, which is crucial for high-efficiency separations. These specifications enable the column to provide excellent peak shapes, high resolution, and robust performance in analytical applications. This configuration is particularly beneficial in optimizing separation conditions for challenging compounds. -
Question:
How do I choose the right HPLC column for my application?
Answer: Selecting the right HPLC column involves considering factors such as the nature of your sample, the desired separation efficiency, and compatibility with your mobile phase. The MACHEREY-NAGEL 720936.4 Nucleosil 100-5 C18 AB column is an excellent choice for non-polar analytes due to its C18 stationary phase. Additionally, understanding your specific method requirements, such as column dimensions and particle size, can enhance analytical performance. Experimenting with different columns may also help to optimize your method further. -
Question:
What type of applications is the Nucleosil 100-5 C18 AB Column recommended for?
Answer: The Nucleosil 100-5 C18 AB Column is recommended for a variety of applications including pharmaceutical analysis, environmental monitoring, and the assessment of food products. Its versatile C18 phase accommodates the separation of a wide range of compounds, from small organic molecules to larger biomolecules. The column’s suitability for diverse analytes makes it an essential tool for laboratories involved in method development and routine analysis aimed at ensuring quality and compliance. -
Question:
Can the MACHEREY-NAGEL Nucleosil 100-5 column be reused?
Answer: The MACHEREY-NAGEL Nucleosil 100-5 column can be reused, provided it is adequately maintained and operated under recommended conditions. Proper cleaning and storage practices are crucial to prolonging its lifespan and ensuring consistent performance. It is advised to regularly assess column performance through parameters such as resolution and back pressure, and to replace the column if significant degradation is observed. This longevity makes the Nucleosil columns a cost-effective choice for high-throughput laboratories. -
Question:
What mobile phases work best with the Nucleosil 100-5 C18 AB Column?
Answer: The Nucleosil 100-5 C18 AB Column works effectively with a variety of mobile phases, including the commonly used mixtures of water and organic solvents such as acetonitrile or methanol. Adjusting the polarity of the mobile phase can significantly affect retention times and separation efficiency. For optimal results, it’s advisable to trial different ratios of organic to aqueous solvents while monitoring the separation quality of your specific analytes. This adaptability allows researchers to fine-tune their methods for effective separations. -
Question:
Is the Nucleosil 100-5 C18 AB Column compatible with all commonly used solvents?
Answer: Yes, the Nucleosil 100-5 C18 AB Column is compatible with a wide range of commonly used solvents in HPLC, including polar and non-polar solvents like methanol, acetonitrile, and water. However, users should avoid highly aggressive solvents that could damage the stationary phase. When preparing your mobile phase, consider the polarity and viscosity of the solvents to ensure optimal flow and separation efficiency. Such compatibility makes the column versatile for various analytical applications in different industries. -
Question:
What precautions should be taken when handling HPLC columns?
Answer: When handling HPLC columns, including the Nucleosil 100-5 C18 AB, certain precautions should be followed to ensure optimal performance. Always handle columns with clean gloves to avoid contamination and ensure that fittings are properly tightened to prevent leaks. Regularly equilibrate the column before use and avoid exceeding recommended flow rates to prevent physical damage. Following these guidelines enhances the column's longevity and maintains the integrity of your analytical results. -
Question:
Where can I buy MACHEREY-NAGEL 720936.4 Nucleosil 100-5 C18 AB HPLC 1 Column in Grenada?
Answer: You can purchase the MACHEREY-NAGEL 720936.4 Nucleosil 100-5 C18 AB HPLC 1 Column from Ubuy, which is a reliable online marketplace in Grenada. Ubuy offers a wide variety of lab equipment and analytical supplies, making it a convenient choice for researchers and professionals. You can explore their extensive range of HPLC columns and other chromatography accessories to support your laboratory needs.
MACHEREY-NAGEL LC Columns & Column Supplies Editorial Review
Customer Reviews & Ratings
-
5 Star
100%
-
4 Star
0%
-
3 Star
0%
-
2 Star
0%
-
1 Star
0%
Review this product
Share your thoughts with other customers
Product Price History
Important information
- Limitations : For products shipped internationally, please note that any manufacturer warranty may not be valid; manufacturer service options may not be available; product manuals, instructions, and safety warnings may not be in destination country languages; the products (and accompanying materials) may not be designed in accordance with destination country standards, specifications, and labeling requirements; and the products may not conform to destination country voltage and other electrical standards (requiring use of an adapter or converter if appropriate). The recipient is responsible for assuring that the product can be lawfully imported to the destination country. When ordering from Ubuy or its affiliates, the recipient is the importer of record and must comply with all laws and regulations of the destination country.
- Not all the products listed on Ubuy are for sale, as Ubuy is a global search engine. Products are subject to export/trade regulations.
XCD 2697
Order now and get it around Tuesday, August 11
This item is not restrict in my country.(Please click on above link if this item is not restrict in your country, So our team will review and allow.)
QTY:
Ubuy works hard to protect your security and privacy. Our advanced payment security system ensures confidentiality by encrypting your information during transmission using AES (Advanced Encryption Standards) and SSL (Secure Socket Layer) protocols. Your payment details are 100% secure as we do not share your payment details with third party sellers.
Features & Benefits
- Totally porous spherical silicas with a uniform SiO2 structure.
- Endcapped with a pore size of 100 Å and a particle size of 5 µm.
- Utilizes hydrophobic interactions for effective separation.
- Well-regarded as routine packing for various chromatography applications.
- Pioneering product in HPLC technology.
- Ensures reliability and precision in analytical procedures.